Skip to main content
Enquire Now

FCMF/FCVF-A Series

Cooling Only

FCMF/FCVF-A Series

FCMF FCVFA

Daikin’s FCMF/VF range of cassette air conditioners are designed to redefine air conditioning with 360⁰ airflow that cools the entire room to ensure comfort that never feels cold. Its revolutionary uniform air distribution guarantees comfort that spreads more widely. Besides this, the unit boasts of some of the amazing features that make it a perfect choice for summers.

Product Category

Available in (kW):

Salient Features

D III net compatible

D III net compatible

Connection to a centralised control system is available without need for an optional adaptor. Available in Inverter Series only.

Drain pump mechanism

Drain pump mechanism

Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.

Individual air flow control

Individual air flow control

Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Night quiet operation

Night quiet operation

The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.

Swing pattern selection

Swing pattern selection

You can freely set air discharge settings by remote controller. One can choose from Standard setting, Draft prevention setting and Ceiling soiling prevention setting.

Silver ION antibacterial drain pan

Silver ION antibacterial drain pan

A built-in anti-bacterial treatment that uses silver ion in the drain pan prevents the growth of bacteria, and mould that cause odours & clogging.

Auto restart

Auto restart

If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.

Humidity sensor

Humidity sensor

Not only temperature but also humidity is detected, and adjustments are made for comfortable air conditioning.

Energy consumption monitoring

Energy consumption  monitoring

Past power consumption is displayed for the current and previous days as well as in weekly and yearly intervals.

Specification

Round Flow Cassette Cooling Only - 5 Star Inverter R-32 (FCMF-Series)

inverter-5star-r32
ModelIndoor unitFCMF50ARV169FCMF71ARV169FCMF90ARV169FCMF100ARV169
Outdoor unitRZMF50BRV169RZMF71BRV169RZMF90BRV169RZMF100BRV169
RemoteWirelessOptionalBRC91A152
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code With SensingBYCQ125EEF6
Power supply   230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph
Cooling capacity -Rated (min ~max)kW5.27(3.2~5.6)7.1 (3.2~8.0)8.79 (4.5~10.1)10.51 (5.0~11.2)
Power consumptionCooling-RatedkW1.361.902.423.10
Annual Power ConsumptionkWh784.561057.111365.21804.81
ISEER / StarsWh/Wh5.2/5 Star5.2/5 Star5.1/5 Star4.51/5 Star
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min23 / 21 / 18.5 / 16 / 13.534.5 / 31 / 27.5 / 24 / 20
cfm812/742/653/565/4771218/1095/971/848/706
Sound level (H/HM/M/ML/L)dB(A)37 / 34.5 / 32 / 29.5 / 27.545 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD)Unitmm256X840X840298X840X840
Panelmm50X950X950
Machine weightUnitkg2225
Panelkg5.5
Drain mmVP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour  Ivory White
CompressorType Hermetically Sealed Swing Type
 Motor outputkW1.31.31.61.6
Refrigerant R32
Refrigerant chargekg1.091.32.82.8
Sound levelCoolingdB(A)48505151
Dimensions (HXWXD)mm595x845x300595x845x300990x940x320990x940x320
Machine weightkg36.5405757
Certified operation range°CDB21 ~ 52
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
Max. interunit piping lengthm30305050
Max. installation level difference m20203030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only - 5 Star Inverter R-32 (FCMF-Series)

inverter-r32
ModelIndoor unitFCMF125ARV169FCMF125ARV169FCMF140ARV169FCMF140ARV169
Outdoor unitRZMF125BRV169RZMF125BRY169RZMF140BRV169RZMF140BRY169
RemoteWirelessOptionalBRC91A152
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code With SensingBYCQ125EEF6
Power supply   230V/50Hz/1ph400V/50Hz/3ph230V/50Hz/1ph400V/50Hz/3ph
Cooling capacity -Rated (min ~max)kW12.5 (5.7~14.0)12.5 (5.7~14.0)14.0 (6.2~15.5)14.0 (6.2~15.5)
Power consumptionCooling-RatedkW4.264.084.954.95
Annual Power ConsumptionkWh2359.132330.022644.862644.86
ISEER / StarsWh/Wh4.10/5 Star4.15/5 Star4.1/5 Star4.1/5 Star
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min36.5/33/29/25/21
cfm1288/1165/1024/882/741
Sound level (H/HM/M/ML/L)dB(A)46/43/40/36/32.5
Dimensions (HXWXD)Unitmm298X840X840
Panelmm50X950X950
weightUnitkg25
Panelkg5.5
Drain mmVP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour  Ivory White
CompressorType Hermetically Sealed Swing Type
 Motor outputkW2.42.42.42.4
Refrigerant R32
Refrigerant chargekg3.13.13.13.1
Sound levelCoolingdB(A)55555555
Dimensions (HXWXD)mm990x940x320990x940x320990x940x320990x940x320
Machine weightkg69696969
Certified operation range°CDB21 ~ 52
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
Max. interunit piping lengthm50505050
Max. installation level difference m30303030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only - 4 Star Inverter R-32 (FCVF-Series)

inverter-4star-r32
ModelIndoor unitFCVF50ARV169FCVF71ARV169FCVF90ARV169FCVF100ARV169
Outdoor unitRZVF50BRV169RZVF71BRV169RZVF90BRV169RZVF100BRV169
RemoteWirelessOptionalBRC91A152
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code With SensingBYCQ125EAF6
Power supply   230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph
Cooling capacity -Rated (min ~max)kW5.27 (3.2~5.6)7.1 (3.2~8.0)9.0 (4.5~10.1)10.51 (5.0~11.2)
Power consumptionCooling-RatedkW1.452.012.513.26
Annual Power ConsumptionkWh842.771133.541436.162057.73
ISEER / StarsWh/Wh4.85/4 Star4.85/4 Star4.85/4 Star3.95/4 Star
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min23 / 21 / 18.5 / 16 / 13.534.5 / 31 / 27.5 / 24 / 20
cfm812/742/653/565/4771218/1095/971/848/706
Sound level (H/HM/M/ML/L)dB(A)37 / 34.5 / 32 / 29.5 / 27.545 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD)Unitmm256X840X840298X840X840
Panelmm50X950X950
WeightUnitkg2225
Panelkg5.5
Drain mmVP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour  Ivory White
CompressorType Hermetically Sealed Swing Type
 Motor outputkW1.31.31.61.6
Refrigerant R32
Refrigerant chargekg1.091.32.82.8
Sound levelCoolingdB(A)48505151
Dimensions (HXWXD)mm595x845x300595x845x300990x940x320990x940x320
Machine weightkg36.5405757
Certified operation range°CDB21 ~ 52
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
Max. interunit piping lengthm30305050
Max. installation level difference m20203030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only - 4 Star Inverter R-32 (FCVF-Series)

inverter-r32
ModelIndoor unitFCVF125ARV169FCVF125ARV169FCVF140ARV169FCVF140ARV169
Outdoor unitRZVF125BRV169RZVF125BRY169RZVF140BRV169RZVF140BRY169
RemoteWirelessOptionalBRC91A152
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code With SensingBYCQ125EAF6
Power supply   230V/50Hz/1ph400V/50Hz/3ph230V/50Hz/1ph400V/50Hz/3ph
Cooling capacity -Rated (min ~max)kW12.5 (5.7~14.0)12.5 (5.7~14.0)14.0 (6.2~15.5)14.0 (6.2~15.5)
Power consumptionCooling-RatedkW4.454.455.255.12
Annual Power ConsumptionkWh2513.482513.482886.342852.03
ISEER / StarsWh/Wh3.85/4 Star3.85/4 Star3.75/4 Star3.80/4 Star
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min36.5/33/29/25/21
cfm1288/1165/1024/883/742
Sound level (H/HM/M/ML/L)dB(A)46/43/40/36/32.5
Dimensions (HXWXD)Unitmm298X840X840
Panelmm50X950X950
weightUnitkg25
Panelkg5.5
Drain mmVP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour  Ivory White
CompressorType Hermetically Sealed Swing Type
 Motor outputkW2.42.42.42.4
Refrigerant R32
Refrigerant chargekg3.13.13.13.1
Sound levelCoolingdB(A)55555555
Dimensions (HXWXD)mm990x940x320990x940x320990x940x320990x940x320
Machine weightkg69696969
Certified operation range°CDB21 ~ 52
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
Max. interunit piping lengthm50505050
Max. installation level difference m30303030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com

X